HN-6 Rack Bright Nickel Plating
Commodity Name
HN-6 Rack Bright Nickel Plating
Composition and Working Conditions

 

Nickel sulfate

Nickel chloride

Boric acid

Brightener HN-6

Softener HN-5(2X)

Auxiliary agent HN-1

Wetting agent HN-19

Temperature 

pH value

Current density

Agitation                       

Filtration

Consumption:

Brightener HN-6

240~300g/L

45~60g/L

40~50g/L

0.5~1.0mL/L

8~12mL/L

3~5mL/L

1~2mL/L

50~60℃

4.0~4.8

2~10 A/dm2

Air agitation or mechanical agitation

Continuous cycle filtration

 

200~250mL/1000A.H

 

Application and Advantage

 

1. Bright white and esthetic coating with good flexibility.

2. Good distribution and excellent covering of working bath.

3. High-speed brightening and excellent leveling.

4. Wide range of operation and high tolerance against impurities, especially suitable for nickel plating of zinc alloy die cast parts.

5. Suitable for nickel plating after acid copper plating.