HN-736 Activator
Commodity Name
HN-736 Activator
Composition and Working Conditions

 

HN-736 Activator                                    3-7 ml/L

Stannous Chloride                                 3-5 g/L

Hydrochloric Acid36%                     250-300 ml/L

Temperature                                          20-35

Time                                                      2-6 minutes

Agitation                                                slight mechanical agitation

Filtration                                                recycle filtration with non-metal Pump

 

Application and Advantage

 

1. It has stable activating performance and long working life.

2. It can be used as catalyst in electroless nickel or electroless copper plating.